top of page
Helkama RFA-FRHF (i) +WSR/WJR 250V
Helkama RFA-FRHF (i) +WSR/WJR 250V
Fire Resistant + Water Spray Resistant and/or Water Jet Resistant collectively and individually screened instrumentation and communication cable 250V
Manufacturer:
Helkama
Product Description
Marine approved, Fire Resistant + Water Spray Resistant and/or Water Jet Resistant, collectively and individually screened instrumentation and communication cable for fixed installation in most areas and on open deck in ships and offshore units. Especially intended to ensure the availability of all critical transportation-, comfort- and safety systems, i.e. to meet the concepts of; Orderly Evacuation (3 hours burning time) and Safe Return to Port (fire test with simultaneous Water Spray / Water Jet + mechanical shocks) to simulate the firefighting conditions.
Main Characteristics
Rated Voltage | 150/250V (300V) |
Flame-retardant | IEC 60332-1-2 |
IEC 60332-3-22 |
Halogen-free | IEC 60754 |
Smoke emission | IEC 61034 |
Oil resistance | IEC 60811-404 (only SHF2) |
Technical Reference
Specifications
Armour | No |
Voltage Rating | 250V |
Number of Conductors | 1 - 30 |
Conductors Cross Section | 0,75 - 1,5 mm2 |
Conductor | Stranded |
Conductor Insulation | XLPE |
Conductor Max Temperature | + 90°C |
Max Operating Temperature | + 80°C |
Min Operating Temperature | - 40°C |
Sheath Insulation | SHF1 |
Sheath Colour | Orange |
Halogen-free | Yes |
Flame-retardant | Yes |
Fire-resistant | Yes |
EMC | No |
Oil-resistant | No |
Water Spray/Jet Resistant | Yes |
Marine Approvals | ABS, BV, CCS, DNV-GL, KR, LR, NK, RINA, RMRS |
bottom of page